- There are issues with 'decimal commas' - particularly in the admin interface, but also in the 'engine'
- At some browser widths, the (admin interface?) menu wraps and obscures some of the content
- Not all 'out of range' values in Davis logger data are catered for - should be fixed in 3010
- Realtime ftp may not recover from network/server issues
- Dominant wind direction figures not reloaded from today.ini (calc may also be wrong) - should be fixed in 3015
- TCP/IP data stops when using Virtual VP (and possibly other Davis TCP/IP connections?) - hopefully fixed in 3018
- FTP uploads can go to wrong directory if there are connection issues - should be fixed in 3021
- 'Sharing violation' on a .ini file (e.g. month.ini) when new high wind run set - should be fixed in 3021
- Davis UV graph is in integers if you use decimal commas - should be fixed in 3022
- Doesn't check for out of range Lux figures (Fine Offset) - should be fixed in 3022
- Davis data stops being read
- Problem with setting/unsetting 'send solar' in Wunderground and PWS Weather settings - should be fixed in 3023
- Should check that a WU update isn't already in progress before starting a new one - should be fixed in 3023
- Davis extra temps and DPs give invalid values when sensor not present - should be fixed in 3024
- Moon phases are wrong - should be fixed in 3024
- Problem with 'wake console' code on Davis TCP/IP connections - should be fixed in 3024
- <#tomorrowdaylength> calculation is wrong - should be fixed in 3025
- High min temp date is wrong - should be fixed in 3025
- Monthly alltime record broken on 1st of month before 0900/1000 gets assigned to wrong month, if using 0900/1000 rollover - should be fixed in 3025
- Crashes at startup if sun is always up (or down). There are other related issues with things like daylight length at higher latitudes - should be fixed in 3026
- Davis wind chill is always degrees C if logger data is being used - should be fixed in 3026
- Communication issues with Davis IP loggers - should be improved in 3026
Rounding issues with Beaufort calculations - should be fixed in 3026- Use of 'periodic disconnect' for Davis IP connections causes crash - should be fixed in 3027
- Twitter stops working on some systems - should be fixed in 3027
- Data reading thread with Davis serial/USB stations can crash if invalid data received (bug introduced in 3026) - should be fixed in 3028
- 'Recent data' missing if duplicate timestamps in log files - should be fixed in 3028
- Davis 'periodic disconnect' still has problems, on Windows only - should be fixed in 3029
- Spurious small 'rain last hour' etc when multiplier used - should be fixed in 3029
- Exceptions can occur when enabling or disabling FTP logging dynamically - should be fixed in 3029
- WMR928TempChannel setting doesn't also do humidity - should be fixed in 3029
- A fix to the 'dp' code for latitude and longitude in 3029 has stopped it working - should be fixed in 3030
- Graph data loaded from logs at start up is always for last 24 hours rather than configured period - should be fixed in 3031
- Rain in last 24 hours is actually for configured graph period - should be fixed in 3031
- A zero in location seconds field can sometimes cause problems - should be fixed in 3031
- Davis reception stats are still read every couple of minutes rather than every 15 minutes - should be fixed in 3031
- Checksum validation for Instromet is wrong, so all data is rejected - should be fixed in 3032
- Dominant wind direction is wrong when Davis logger data is used (i.e. when catching up) - should be fixed in 3032
- Easyweather.dat reading interval is an integer, should be a float as in Cumulus 1 - should be fixed in 3033
- All-time and monthly all-time gust don't always get updated on Davis stations if figure from LOOP2 is used - should be fixed in 3033
- Crash while parsing data from Instromet station - should be fixed in 3033
- External program shouldn't run until all pages processed - should be fixed in 3033
- Default file encoding on Mono is UTF-8 rather than ANSI, so unsetting UTF-8 options have no effect - should be fixed in 3035
- NOAA files with UTF-8 option shouldn't use BOM - should be fixed in 3035
- Cloudbase unit not supplied to UI gauges - should be fixed in 3035
- Auto ftp of NOAA reports can happen before reports are complete - should be fixed in 3035
- Doesn't pre-load graph data etc from log files for 'Easyweather.dat' input - should be fixed in 3036
- NOAA files without UTF-8 selected should use ISO-8859-1 not ASCII - should be fixed in 3036
- Problems with parsing Instromet responses due to Unix newlines - should be fixed in 3036
- Davis Leaf Wetness values are not read correctly - should be fixed in 3037
- Processing of Davis archive data can stop after day rollover - should be fixed in 3037
- Web files without UTF-8 selected should use ISO-8859-1 not ASCII (causes 'odd' characters to appear) - should be fixed in 3037
- End of month/year copies of month.ini and year.ini are incorrectly named if 0900 start of day in use - should be fixed in 3037
- Dayfile.txt viewer can display an error message if dayfile.txt from Cumulus 1 is used - should be fixed in 3037
- CWOP temperature incorrectly formatted when below 0F - causes CWOP to read as zero - should be fixed in 3037
- Another problem with date parsing in Instromet logger entries - should be fixed in 3038
- Monthly rain record may get logged at start of month using previous month's total - should be fixed in 3038
- Web updates don't work at intervals that aren't factors of 60 - should be fixed in 3038
- Max and min comparison totals wrong on NOAA annual report - should be fixed in 3038
- Some timer-based actions (e.g. data logging, graph plotting, realtime FTP and realtime SQL update) can happen before first data is read
- Instromet logger interval gets set to seconds rather than minutes - Should be fixed in 3039
- End of day reset code gets the date of day just ending wrong for 0900 rollovers
- Should calculate rain rate for Instromet stations - should be fixed in 3042
- RainLast24Hour in dashboard data is always zero - should be fixed in 3042
- The one second read timeout introduced in 3041 for Davis stations is not long enough for Weatherduino - needs to be configurable - should be fixed in 3042
Doesn't use configured FTP port - should be fixed in 3042- Sunshine hours not updated when using Davis archive data - should be fixed in 3042
- RG11 devices do not function on Linux OS (COM port values are incompatible)
- If MySQL Port value is corrupt/missing in Cumulus.ini CumulusMX will crash